電流: 829 Terms and Phrases
- 電流
- electric current
- power current
- 熱電流
- thermoelectric current
- 地電流
- earth-current
- earth current
- natural current
- terrestrial current
- Telluric current
- 逆電流
- reverse current
- inverse current
- backward current
- reversed current
- 過電流
- excess current
- over current
- over-current
- overcurrent
- 電流計
- amperometer
- ammeter
- ampere meter
- 暗電流
- dark current
- parasitic current
- idling current
- 光電流
- photocurrent
- photoelectric current
- 環電流
- ring current
- Aromatic ring current
- 残留電流
- post arc current
- post-arc current
- residual current (for protection)
- 三相電流
- three-phase currents
- 電束電流
- displacement current
- 単向電流
- unidirectional current
- 点弧電流
- striking current of arc
- 再生電流
- regenerative current
- 定格電流
- rated current
- current rating
- 定常電流
- steady-state current
- 短絡電流
- short-circuit current
- 電流滴定
- amperometric titration
- 無効電流
- reactive current
- quadrature current
- qudrature component
- wattless current
- 迷走電流
- leakage power
- leaking current
- stray current
- 始動電流
- starting current
- striking current
- うず電流
- eddy current
- foucault current
- 遮断電流
- breaking current
- interrupting current
- 降水電流
- precipitation current
- 管内電流
- electric current in pipeline
- 逆相電流
- negative-phase-sequence current
- 許容電流
- allowable current
- permissible current
- 動作電流
- operating current
- actuating current
- 脈動電流
- intermittent current
- pulsating current
- ripple current
- 定電流式
- constant current type
- 漏洩電流
- leakage current
- leak current
- 励磁電流
- excitation current
- exciting current
- 誘導電流
- induced current
- induction current
- 交番電流
- alternating current
- AC
- 永久電流
- permanent current
- persisent current
- persistent current
- 高圧電流
- high-voltage current
- high-tension current
- 変位電流
- displacement current
- 入力電流
- input
- incoming current
- 電流密度
- current density
- electric current density
- 分極電流
- polarization current
- polarizing current
- 電流測定
- amperometry
- amperometric
- 限界電流
- demarcation current
- limiting current
- 電流回生
- current regeneration
- 差動電流
- differential current
- differential current measurement
- longitudinal differential current
- 放電電流
- discharge current
- discharging current
- 電流特性
- characteristic influenced by current
- 陽極電流
- anode current
- plate current
- 電流容量
- current capacity
- current carrying capacity
- 電流増幅
- current amplification
- 鉄損電流
- core loss current
- core-loss current
- 定電流源
- constant current source
- 重疊電流
- superimposed current
- 重畳電流
- superimposed current
- 接地電流
- earth current
- ground current
- 拘束電流
- locked rotor current
- 間欠電流
- intermittent current
- 大電流測定
- measurement of large current
- m相電流源
- m-phase current source
- 多相電流源
- polyphase current source
- 接地線電流
- grounding conductor current
- 渦電流解析
- eddy current analysis
- 電流力計形
- electro-dynamic type
- electrodynamometer type
- 大電流容量
- large current capacity
- 初磁化電流
- initial magnetizing current
- 理想電流源
- ideal current source
- 熱刺激電流
- thermally stimulated current
- 同期化電流
- synchronizing current
- 4相電流源
- 4-phase current source
- 3相電流源
- 3-phase current source
- 2相電流源
- 2-phase current source
- 逆阻止電流
- reverse blocking current
- 単相電流源
- single-phase current source
- 反磁性電流
- diamagnetic current
- リーク電流
- leak current
- Leakage (semiconductors)
- 漏えい電流
- leakage current
- leak current
- 渦電流継手
- eddy current coupling
- eddy current control
- 外向き電流
- outward current
- efflux
- out going current
- イオン電流
- ionic current
- ion current
- ゲート電流
- gating current
- gate current
- 電流制限器
- current limiter
- Current limiters
- 差動電流計
- differential ammeter
- 逆吸収電流
- discharge current of absorbed charge
- 電流供給損
- current supply loss
- 電流進行波
- current travelling wave
- 小電流遮断
- capacitive current switching
- 定電流制御
- ACR constant current control or automatic current regulator
- 電流循環式
- circulating current type
- 波高電流計
- crest ammeter
- crest ampere meter
- 電流平衡形
- current balance type
- 電流増幅率
- current amplification factor
- 定電流特性
- constant current characteristic
- 定電流充電
- constant-current charge
- 定電流方式
- constant-current system
- 定電流変調
- constant-current modulation
- 定電流放電
- constant-current discharge
- 電流遮断器
- circuit breaker
- circuit breaker box
- 全出力電流
- total output current
- 光誘起電流
- photoinduced current
- 高電流駆動
- high-current drive operation
- 電極逆電流
- inverse electrode current
- 順阻止電流
- forward blocking current
- 需要電流計
- ampere demand meter
- 高周波電流
- high‐frequency current
- ピーク電流
- peak current
- summit current
- ゆらぎ電流
- fluctuating current
- 定電流負荷
- current source load
- 定電流電源
- constant‐current power source
- 定電流電解
- constant-current electrolysis
- electrolysis at constant current
- galvanostatic electrolysis
- 光電子電流
- photoelectric current
- 過電流保護
- overcurrent protection
- 漏れ電流計
- Leakage current ammeter
- 逆電流保護
- reverse-current protection
- 最大短絡電流
- maximum asymmetric short-circuit current
- 最小溶断電流
- minimum fusing current
- 最小動作電流
- minimum working current
- 磁気電流効果
- magnetogalvanic effect
- magneto-galvanic effect
- 励磁突入電流
- magnetizing inrush current
- 許容最大電流
- permissible current carrying capacity
- 公称放電電流
- nominal discharge current
- 過電流リレー
- OCR(OC) Over Current Relay
- 電流磁気効果
- galvano magnetic effect
- 接地漏れ電流
- earth leakage current
- 地絡故障電流
- earth fault current
- ホール電流計
- Hall effect current meter
- 瞬時電流制御
- instantaneous current control
- 誘導電流密度
- induced current density
- 通過事故電流
- through fault current
- 表面漏れ電流
- surface leakage current
- 対称遮断電流
- symmetrical breaking current
- 零相循環電流
- zero-phase-sequence circulating current
- zero-sequence circulating current
- I0th I0 through
- 零パワー電流
- zero power current
- 電圧電流特性
- volt-ampere characteristic
- 電圧電流波形
- voltage and current waveform
- 突発短絡電流
- sudden short-circuit current
- 破壊前駆電流
- prebreakdown current
- 一次三相電流
- primary three-phase currents
- 単相瞬時電流
- single phase instantaneous current
- 二次三相電流
- secondary three-phase currents
- 二次電流制限
- secondary current limitation
- 迷走電流腐食
- stray current corrosion
- 過電流継電器
- overcurrent relay
- over current relay
- 最大誘導電流
- maximum conduction current
- 電流一致選択
- coincident-current selection
- トンネル電流
- tunnel current
- tunneling current
- 逆方向性電流
- opposite directed current
- opposite direction current
- 電流差動方式
- current differential replaying method
- 直流電流遮断
- dc current interruption
- 直流漏れ電流
- DC leakage current
- 電流時間曲線
- current-time curve
- 電流雑音電圧
- current-noise voltage
- 臨界電流密度
- critical current density
- 定電流変圧器
- constant-current transformer
- 定電流発電機
- constant-current generator
- 速波電流駆動
- Fast Wave Current Drive
- 加熱電流駆動
- Heating and Current Drive
- 過電流遮断器
- overcurrent breaker
- overcurrent circuit breaker
- 保護導体電流
- protective conductor current
- 電流電圧曲線
- current-voltage relationship
- 電流電圧関係
- current-voltage relationship
- 電流導入端子
- vacuum current feedthrough
- 零相電流装置
- residual current device
- 定電流電解法
- chronopotentiometry
- 残留電流装置
- residual current device
- 等価雑音電流
- equivalent noise current
- 外装漏れ電流
- enclosure leakage current
- 最大不溶断電流
- maximum non-fusing current
- 最小アーク電流
- minimum arc current
- minimum arcing current
- 極小動作電流値
- minimum operating current
- 磁気誘導地電流
- magnetotelluric current
- magneto-telluric current
- 過電流継電方式
- over-current protection
- overcurrent relaying sytem
- 中性子電流密度
- neutron current density
- 非誘導電流駆動
- non-inductive current drive
- 非循環電流方式
- non-circulating current type
- 界磁電流リレー
- field current relay
- 故障電流計算法
- fault current analysis
- 渦電流クラッチ
- eddy current clutch
- 地磁気誘導電流
- GIC Geomagnetically Induced Current
- 入力電流高調波
- input harmonic current
- 真性電流増幅率
- intrinsic current amplification
- 中間電流供給盤
- intermediate battery supply board
- 起誘導電流曲線
- inducing current curve
- 起誘導電流解析
- inducing current analysis
- 大電流スイッチ
- heavy-current switch
- 高調波電流抑制
- harmonic current suppression
- 電源電流高調波
- supply current harmonics
- 対称多相電流源
- symmetrical polyphase current source
- 不平衡三相電流
- unbalanced three phase current
- 不足電流継電器
- undercurrent relay
- 電流の表示方向
- reference direction of a current
- 定格リプル電流
- rated ripple current
- 定格コイル電流
- rated coil current
- 商用周波数電流
- power-frequency current
- 対称2相電流源
- quarter-phase current source
- 進み小電流遮断
- small capacitive current breaking
- 遅れ小電流遮断
- small inductive current breaking
- SLF電流遮断
- SLF current interruption
- 正弦波入力電流
- sinusoidal input current
- 電流調整器端子
- current regulator terminal
- 電流制限継電器
- current limit relay
- 渦電流ブレーキ
- eddy current brake
- 渦電流式選別機
- eddy current separator
- 渦電流探傷試験
- eddy current examination
- シナプス後電流
- postsynaptic current
- カルシウム電流
- calcium current
- Ca2+ current
- 電流切換形論理
- current mode logic CML
- 電流検出継電器
- current detecting relay
- 電流差動継電器
- current differential relay
- 電流帰還増幅器
- current feedback amplifier
- 電流センサレス
- current sensor-less
- 電流検出リレー
- current-sensing relay
- 電流制御負抵抗
- current-controlled negative resistance CCNR
- 電流平衡継電器
- current-balance relay
- 自動電流リレー
- automatic current relay
- 過電流設計倍数
- CDF current design factor
- 自動電流調整器
- automatic current regulator
- 非対称遮断電流
- asymmetrical breaking current
- 電機子電流制御
- armature current control
- 標準電流発生器
- current calibrator
- standard current generator
- 過電流保護回路
- overcurrent protection circuit
- 水銀電流遮断器
- mercury interrupter
- 信号電流微小時
- when signal current is very small
- 電子線誘起電流
- electron-beam induced current
- 重畳電流鍍金法
- superimposed current electroplating
- 電流の磁気作用
- magnetic action of electric current
- 出力電流定格値
- output current rating
- 渦電流探傷検査
- eddy current testing (ECT)
- 定電流電解重合
- galvanostatic electropolymerization
- 暗電流ドレイン
- dark current drain
- 過電流保護装置
- overcurrent protective device
- 磁気誘導地電流法
- magnetotelluric method
- 可動コイル電流計
- moving-coil ammeter
- 線路充電電流遮断
- line-charging current breaking
- 縦電流防止コイル
- longitudinal retardation coil
- 電圧・電流位相差
- phase angle between voltage and current
- phase difference between voltage and current
- 逆相過電流継電器
- negative-phase-sequence overcurrent relay
- 中性点過電流保護
- neutral current protection
- ground overcurrent protection
- 地絡過電流リレー
- OCGR(OCG) Ground Over Current Relay earth-fault overcurrent relay
- 事故電流遮断時間
- fault current interruption time
- 外枠接地電流保護
- frame leakage protection
- case ground protection
- frame ground protection
- 発生-再結合電流
- generation-recombination current
- ゲートトリガ電流
- gate trigger current
- 地絡過電流継電器
- earth-fault overcurrent relay
- ground overcurrent relay
- しきい値電流密度
- threshold current density
- 三相突発短絡電流
- sudden three-phase short circuit current
- サージ波高電流計
- surge-crest ammeter
- 電圧と電流の波形
- voltage and current waves
- 逆方向電流増幅率
- reverse current amplification factor
- のこぎり波状電流
- sawtooth current
- リレーの保持電流
- ratch current of relay
- 空間電荷制限電流
- space-charge limiting current
- 単相電流ベクトル
- single phase current vector
- うず電流式動力計
- eddy current dynamometer
- 電流調整器コイル
- current regulator coil winding
- 永久電流スイッチ
- persistent current switch
- 電流計測システム
- current measurement system
- 定電流ダイオード
- current regulation diode
- 電流差動継電方式
- current differential protection
- 方向過電流継電器
- directional over-current relay
- directional-over-current relay
- directional-overcurrent relay
- 電流給電アンテナ
- current-fed antenna
- 電流シミュレータ
- current simulator
- 電流形インバータ
- current source inverter
- 電流比較継電方式
- current comparison protection
- クランプ型電流計
- current clamp meter
- 交流過電流リレー
- AC overcurrent relay
- コレクタ遮断電流
- collector cut-off current
- 電流(電圧)特性
- current (voltage) characteristic
- コモンモード電流
- common mode current
- 中性粒子電流駆動
- Neutral Beam Current Drive
- 重畳電流めっき法
- superimposed current electroplating
- のこぎり波形電流
- sawtooth current
- フィラメント電流
- filament current
- 電流駆動磁壁移動
- current-induced domain wall motion
- ケーブル充電電流
- cable charging current
- ゼロ電界放出電流
- field‐free emission current
- 過電流引外し装置
- overcurrent tripping device
- 静電チャック電流
- electrostatic chuck current
- ESC current
- もはや電流でない
- no longer current
- 目立つ電流がない
- free from noticeable current
- 電流がこみ上げた
- the currents well up
- 電流の引っ張る力
- the pull of the current
- 太陽圏電流シート
- Heliospheric current sheet
- 磁気誘導地電流探査
- magnetotelluric prospecting
- 渦電流継手付電気機
- motor with eddy-current coupling
- 雷インパルス耐電流
- lightning impulse withstand current
- しゅう動子許容電流
- limiting moving contact current
- 入力オフセット電流
- input offset current
- 高速度過電流リレー
- HOC high-speed overcurrent relay
- 交差電流(継電器)
- transverse differential current
- 電流遮断(遮断器)
- current chopping
- 一次電流 一次電圧
- primary current primary voltage versus slip frequency curves
- 可動コイル型電流計
- moving-coil type ammeter
- ハイテンション電流
- high-tension current
- 渦電流式近接センサ
- eddy current type proximity sensor
- 電流マイナーループ
- current minor loop
- 電流切換形論理回路
- current mode logic circuit
- 電流計切換スィッチ
- ammeter change-over switch
- トートバンド電流計
- taut-band ammeter
- 過電流引外しコイル
- overcurrent trip coil
- 電圧と電流の生成物
- the product of voltage and current
- 始動電流(積算計器)
- minimum running current
- 反限時過電流継電方式
- inverse time-lag overcurrent protection
- インパルス電流発生器
- impulse current generator
- サブスレショルド電流
- subthreshold curren
- 電流電圧調整器の形式
- current-voltage regulator type
- 抑制性シナプス後電流
- inhibitory postsynaptic current
- IPSC
- 興奮性シナプス後電流
- excitatory postsynaptic current
- EPSC
- 電流方向比較継電方式
- directional current comparison protection
- 電流方式(遠隔測定)
- current system
- プラズマ電流(Ip)
- Plasma current (Ip)
- 定電流変圧器の変動率
- regulation of constant-current transformer
- 一定電流の条件の下で
- under constant current conditions
- コイルに電流を流す。
- The electric current flows through the coil.
- ゼロクロス電流検出器
- zero crossing current detector
- 円電流の流れ、液体の
- flow in a circular current, of liquids
- 電圧抑制付過電流継電器
- overcurrent relay with voltage restraint
- 励弧電流(水銀整流器)
- excitation current
- 引はずし電流(遮断器)
- tripping current
- 二次電流フィードバック
- secondary current feedback
- 過負荷電流遮断用継電器
- overload relay
- DPFC電流差動リレー
- DPFC current differential relay
- 搬送波電流共同供給装置
- carrier current supply equipment
- 高速粒子、加熱電流駆動
- Fast Particles, Heating and Current Drive
- 高圧受電用過電流継電器
- Overcurrent Relays for 6.6 kV Receiving
- エミッタカットオフ電流
- emitter cut-of current
- 電源から電流はとらない
- draws no current from the source
- 電流によって生じた磁力
- magnetism produced by an electric current
- 突入電流 励磁突入電流
- inrush current
- 多並列ブリッジ電流増幅器
- multi-parallel bridge type current amplifier
- ファイバー型光電流センサ
- optical fiber current sensor
- 電流補償付不足電圧継電器
- undervoltage relay with current compensation
- 零入力電流(磁気増幅器)
- quiescent current
- 電流分布解析(燃料電池)
- current density analysis
- ディジタル電流差動リレー
- current differential digital relaying system
- 電流循環式表示線継電方式
- circulating current type pilot-wire protection
- アルフベン・ローソン電流
- Alfven-Lawson curren
- アンペアで計る電流の強さ
- the strength of an electrical current measured in amperes
- 電圧や電流の一時的な変動
- a transient variation in voltage or current
- 電流の流れへの材料の対立
- a material's opposition to the flow of electric current
- 零相循環電流 中性線電流
- neutral current
- ゼロ電流ソフトスイッチング
- ZCS zero current soft switching
- 自動的に電流を遮断する装置
- a device for automatically interrupting an electric current
- 円形コイルに電流が流れる。
- A current flows in the circular coil.
- 電流を調節するための抵抗器
- resistor for regulating current
- 正弦的に方向が逆になる電流
- an electric current that reverses direction sinusoidally
- 電流はアンペアーで計られた
- the current was measured in amperes
- 不必要な電流を抑制する装置
- an electrical device for suppressing unwanted currents
- 過電流保護 過電流継電方式
- overcurrent protection
- 交流電流から直電流への転換
- the conversion of alternating current to direct current
- 鋼管の自動渦電流探傷検査方法
- Automated eddy current examination of steel pipes and tubes
- 電圧や電力や電流を増やす行為
- the act of increasing voltage or power or current
- 絶え間なく1方向に流れる電流
- an electric current that flows in one direction steadily
- 電流の流れを阻止する電気装置
- an electrical device that resists the flow of electrical current
- 磁気エネルギー回生電流スイッチ
- magnetic energy recovery current switch MERS
- ゼロ電流スイッチング(ZCS)
- zero current switching
- 一次電流-すべり周波数特性曲線
- primary current versus slip frequency characteristic curves
- 電流が流れる経路となる電気装置
- an electrical device that provides a path for electrical current to flow
- 10アンペアに等しい電流の単位
- a unit of current equal to 10 amperes
- 電流の磁力効果によって鳴るベル
- a bell activated by the magnetic effect of an electric current
- 電流を起こすまたはそれに関する
- concerned with or producing electric current
- 電流によって殺傷できる電気装置
- an electrical device that can injure or kill by means of electric currents
- デュアルループ電流フィードバック
- dual-loop current feedback
- 飽和電流変圧器(発電機の励磁系)
- SCT saturable current transformer
- 蓄積電荷、磁場、または電流を失う
- lose a stored charge, magnetic flux, or current
- コイルに電流が流れると磁石になる
- becomes a magnet when current passes through the coil
- 力は電流と磁場に対して直角である
- the force is at right angles to both the current and the magnetic field
- 磁石と同様に電流にも関連している
- associated with electric currents as well as magnets
- (電流について)方向を逆にするさま
- (of a current) reversing direction
- 電流は磁力を発生することができる。
- An electric current can generate magnetism.
- の蓄積電荷あるいは蓄積電流のような
- as of stored charge or current
- 電流が流れていない不完全な電気回路
- an incomplete electrical circuit in which no current flows
- 電流が流れる導体における電圧の減少
- a decrease in voltage along a conductor through which current is flowing
- 電流などの変化をブラウン官に写す装置
- oscilloscope
- 電圧、電流その他電気系統の異常の有無
- Abnormalities in voltage, amperage and other parts of an electrical system.
- Abnormalities in voltage, amperage and other parts of electrical system.
- 筋収縮に関連した電流を記録したグラフ
- a graphical record of electric currents associated with muscle contractions
- 電流の方向を切り替えるためのスイッチ
- switch for reversing the direction of an electric current
- どこかに運ぶ(水、電流、または波の)
- carry somewhere (of water or current or waves)
- 高周波加熱(高周波電流による誘導加熱)
- high-frequency heating
- highfrequency heating
- 熱が電流によって提供されるどんな炉でも
- any furnace in which the heat is provided by an electric current
- 電流は電圧に正比例し、抵抗に反比例する
- electric current is directly proportional to voltage and inversely proportional to resistance
- 化学反応の結果として電流を供給する装置
- a device that delivers an electric current as the result of a chemical reaction
- 回路で発生する電流は、温度差に比例する
- the current generated in the circuit is proportional to the temperature difference
- 心臓の収縮に伴う電流を記録する医療機器
- medical instrument that records electric currents associated with contractions of the heart
- 体内を通じる電流の通過への反射的な反応
- a reflex response to the passage of electric current through the body
- 過負荷になったとき電流の流れを切断する
- an electrical device that can interrupt the flow of electrical current when it is overloaded
- プラスチックフィルムの熱刺激電流試験方法
- Testing method for thermally stimulated current of plastic films
- 電流によってもたらされる熱に起因する火傷
- a burn caused by heat produced by an electric current
- 脳によって発生する電流を記録する医療機器
- medical instrument that records electric currents generated by the brain
- 電圧又は電流の変動が少ない直流の電源装置
- Direct current power units with lower fluctuations of voltage and current
- せん頭陽極電流が一〇〇アンペア以上のもの
- Cold-cathode tubes with a peak anode current of 100 amperes or more
- せん頭陽極電流が五〇〇アンペア以上のもの
- Assemblies with a peak anode current of 500 amperes or more
- 温度測定のために熱電気の電流を使う温度計
- a thermometer that uses thermoelectric current to measure temperature
- (電流のような)熱で組織を凝結させること
- congealing tissue by heat (as by electric current)
- 国際単位系の元で採用された電流の基礎単位
- the basic unit of electric current adopted under the Systeme International d'Unites
- 化学反応で電流を発生させまたはそれに関する
- pertaining to or producing electric current by chemical action
- 電流の流れによって引き起こされた結合の溶解
- a chemical decomposition reaction produced by passing an electric current through a solution containing ions
- 電流がコイルの中に流れると、鉄は磁石になる
- when current flows in the coil the iron becomes a magnet
- 電界放射電流誘起型エレクトロマイグレーション
- field-emission-induced electromigration
- 高周波で管に数回巻かれる電流の作用で発光する
- luminescence is produced by the action of currents at high frequencies that are wrapped a few turns around the tube
- 誘起された電流によって生じる導電性材料の加熱
- the heating of a conducting material caused by an electric current induced in it
- ソレノイドへの突入電流でノイズが発生します。
- Noise is produced by the sudden flow of current into a solenoid.
- 変動する電圧あるいは電流の波形を記録する装置
- a device for making a record of the wave forms of fluctuating voltages or currents
- 周りを電流が流れるか信号が循環する完全電気回路
- a complete electrical circuit around which current flows or a signal circulates
- ある導体から他の導体へ流れる電流を許容する接触
- contact that allows current to pass from one conductor to another
- 低圧電気設備−第4−43部:安全保護−過電流保護
- Low-voltage electrical installations-Part 4-43: Protection for safety-Protection against overcurrent
- 電池または蓄電池の陰電荷の端末で、電流を供給する
- the negatively charged terminal of a voltaic cell or storage battery that supplies current
- ある電圧の交流電流が別の電圧に変換される電気装置
- an electrical device by which alternating current of one voltage is changed to another voltage
- 近隣の回路の電流変化に対応する回路の起電力の比率
- the ratio of the electromotive force in a circuit to the corresponding change of current in a neighboring circuit
- 低電圧電流の脳の移動によって引き起こされる無意識
- unconsciousness brought about by the passage of a low voltage electric current through the brain
- ミリアンペア単位で目盛りのついた感度の高い電流計
- a sensitive ammeter graduated in milliamperes
- 電位差・電流・電量・カールフィッシャー滴定方法通則
- General rules for methods of potentiometric, amperometric, coulometric, and Karl Fischer titrations
- 多接合太陽電池出力電圧・出力電流の温度係数測定方法
- Temperature coefficient measuring methods of output voltage and output current for multi-junction solar cells and modules
- 回路に電流を発生させる源から得られるエネルギー工率
- the rate at which energy is drawn from a source that produces a flow of electricity in a circuit
- 電流の以前のユニット(SIアンペアより少し小さい)
- a former unit of electric current (slightly smaller than the SI ampere)
- 受け皿の置き換えに比例する電流を発生させるバランス
- a balance that generates a current proportional to the displacement of the pan
- 乾燥固体電気絶縁材料−高電圧小電流耐アーク性試験方法
- Dry,solid insulating materials-Resistance test to high-voltage low-current arc discharges
- 電流が一次コイルを流れ、そこに誘導されるようなコイル
- coil such that current is induced in it by passing a current through the primary coil
- 高速度で大電流のスイッチングを行う機能を有する組立品
- Assemblies with a fast high-current switching function
- コイルの中で磁束が生じさせる電流により磁束を測定する
- meter that measures magnetic flux by the current it generates in a coil
- 発生器またはモーターの回転と固定部分の間の電流を導く
- conducts current between rotating and stationary parts of a generator or motor
- 一次コイルを流れる電流は、二次コイルで電流を誘発する
- current through the primary coil induces current in the secondary coil
- 2つ電極のギャップを電流が流れるとき光を作り出すランプ
- a lamp that produces light when electric current flows across the gap between two electrodes
- 電流を供給するボルタ電池または蓄電池の正電荷を持つ端子
- the positively charged terminal of a voltaic cell or storage battery that supplies current
- アモルファス太陽電池出力電圧・出力電流の温度係数測定方法
- Temperature coefficient measuring methods of output voltage and output current for amorphous solar cells and modules
- 電流が流れると白く発熱する(通例タングステンの)細い針金
- a thin wire (usually tungsten) that is heated white hot by the passage of an electric current
- 米国のほとんどの家庭用電流は毎秒60サイクルの交流である
- In the US most household current is AC at 60 cycles per second
- 電荷の単位で1秒間に1アンペアの電流が運ぶ電荷総量に等しい
- a unit of electrical charge equal to the amount of charge transferred by a current of 1 ampere in 1 second
- 医療用のイオンを組織に挿入するために局所電流を使用する治療
- therapy that uses a local electric current to introduce the ions of a medicine into the tissues
- 熱電子放出で電子が放出されたために2つの電極間に生じる電流
- an electric current produced between two electrodes as a result of electrons emitted by thermionic emission
- 回路内の電流の流れの変化が磁力や起電力を生み出していく過程
- an electrical phenomenon whereby an electromotive force (EMF) is generated in a closed circuit by a change in the flow of current
- 電流の突然の変動から設備を守るために電力線に挿入される装置
- electrical device inserted in a power line to protect equipment from sudden fluctuations in current
- 六角形のメッシュのある電流を流されたワイヤー・ネットワーク
- a galvanized wire network with a hexagonal mesh
- 静電気的プロセス、または磁気プロセスにより、電流を発生する
- produce electric current by electrostatic or magnetic processes
- 直動式指示電気計器 第2部:電流計及び電圧計に対する要求事項
- Direct acting indicating analogue electrical measuring instruments and their accessories Part 2 : Special requirements for ammeters and voltmeters
- 超電導−第2部:臨界電流の試験方法−ニオブ3すず複合超電導線
- Superconductivity-Part 2:Critical current measurement-DC critical current of Nb3Sn composite superconductors
- ディーゼルエンジンにより生成された電流により運転される機関車
- a locomotive driven by the electric current generated by a diesel engine
- その回路で電流を変化することよる回路の起電力(EMF)の生成
- generation of an electromotive force (EMF) in a circuit by changing the current in that circuit
- 電流を研究し、ボルタ電堆を発明した(1745年−1827年)
- studied electric currents and invented the voltaic pile (1745-1827)
- 方向距離リレー。電圧と電流で事故箇所までの距離を特定する方式。
- DZR(DZ) Directional Distance Relay
- 脳を通過して痙攣および昏睡状態を引き起こす強い電流をかけること
- the administration of a strong electric current that passes through the brain to induce convulsions and coma
- 1アンペアの電流が流れるとき1オームの抵抗を越える電位差と同じ
- equivalent to the potential difference across a resistance of 1 ohm when 1 ampere of current flows through it
- 電磁(界磁)極間で回転するコイル(電機子)で電機子に電流を流す
- generator consisting of a coil (the armature) that rotates between the poles of an electromagnet (the field magnet) causing a current to flow in the armature
- 住宅及び類似設備用漏電遮断器—過電流保護装置なし (RCCBs)
- Residual current operated circuit-breakers without integral overcurrent protection for household and similar uses(RCCBs)
- 住宅及び類似設備用漏電遮断器—過電流保護装置付き (RCBOs)
- Residual current operated circuit-breakers with integral overcurrent protection for household and similar uses(RCBOs)
- 小さな電流を検知する、比較するか、あるいは計測するためのメートル
- meter for detecting or comparing or measuring small electric currents
- 需要が供給より大きくなると、ある特定のラインの電流を断ち切ること
- cutting off the electric current on certain lines when the demand becomes greater than the supply
- 入力に対する出力の比として表される、信号電力や電圧や電流の増加量
- the amount of increase in signal power or voltage or current expressed as the ratio of output to input
- 電流が流れる電線にコイルを近づけると、コイルにも電気が流れます。
- When a coil is moved near to a wire with current flowing in it current flows in the coil as well.
- 髪根に電流を通すことによって余分、または不必要な髪を除去すること
- removing superfluous or unwanted hair by passing an electric current through the hair root
- 電流が最初に1つを流れ、次にもう1つを流れるような構成部品の接続
- connection of components in such a manner that current flows first through one and then through the other
- 超電導−第1部:臨界電流の試験方法−ニオブ・チタン合金複合超電導線
- Superconductivity-Part 1:Critical current measurement-DC critical current of Nb-Ti composite superconductors
- 明るさの度合いを調節するために電灯を通る電流を変化させる加減抵抗器
- a rheostat that varies the current through an electric light in order to control the level of illumination
- 放電するために反対方向に電流を通すことにより、バッテリーに加圧する
- energize a battery by passing a current through it in the direction opposite to discharge
- 突然の電圧や電流や負荷の変化によって起きる、システムの一時的な震動
- a short-lived oscillation in a system caused by a sudden change of voltage or current or load
- 電流がナトリウム蒸気のチューブを通り抜けたランプは黄色の光を生じる
- lamp in which an electric current passed through a tube of sodium vapor makes a yellow light
- 燃料/排気系、加熱/電流駆動系、プラズマ計測系などの核融合特有の設備
- equipment unique to fusion reactors such as fueling and pumping heating and current drive systems and diagnostics.
- 結晶系太陽電池セル・モジュールの出力電圧・出力電流の温度係数測定方法
- Temperature coefficient measuring methods of output voltage and output current for crystalline solar cells and modules
- 組織を破壊するために、電流で熱された針の適用(いぼを除去するような)
- application of a needle heated by an electric current to destroy tissue (as to remove warts)
- 再結合して、回路を完成する前に電流が2つ以上の経路に分割される閉回路
- a closed circuit in which the current divides into two or more paths before recombining to complete the circuit
- 原因は電気回路の設置に不備があり致死量の電流が流れなかった為である。
- The cause was inappropriate installation of electronic circuit and mortal current was not generated.
- 1オームの抵抗を越えて流れている1アンペアの電流によって放散される力
- the power dissipated by a current of 1 ampere flowing across a resistance of 1 ohm
- 電流の一部の方向を変える、別の装置と並列に接続した低い抵抗を持つ導体
- a conductor having low resistance in parallel with another device to divert a fraction of the current
- (電流の総量とそれが流れる時間によって決定される)電気の量の測定単位
- a measure of the quantity of electricity (determined by the amount of an electric current and the time for which it flows)
- 電池からの電流を発火プラグで必要とされる高圧電流に変換する誘導コイル
- an induction coil that converts current from a battery into the high-voltage current required by spark plugs
- イオン注入法を用いるものであって、ビーム電流が五ミリアンペア以上のもの
- Coating devices that employ ion implantation method and with a beam current of 5 milliamperes or more
- バイアス電流と比例するそのようなその光がPN接合で放射されたダイオード
- diode such that light emitted at a p-n junction is proportional to the bias current
- 単向電流を生じるために、各サイクルの半分(交互の電流)の方向を逆にする
- reverse the direction of (an alternating electric current) each half cycle so as to produce a unidirectional current
- ローターが回転すると、その突出した腕がそれらに接触し、点火栓に電流を流す
- as the rotor turns its projecting arm contacts them and current flows to the spark plugs
- 上述のように、接合部で過剰な暗電流を発生する多くの他のメカニズムがある。
- As described above, there are a number of other mechanisms which generate excess dark currents at junctions.
- パワー・デバイスは、大電流を通し高電圧をサポートするために広く用いられる。
- Power devices are widely used to carry large currents and support high voltages.
- その結果、一つ以上の並列接続されたサイリスタに電流が集中して熱暴走に到る。
- This may lead to current concentration on one or more thyristors connected in parallel, which may result in thermal run-away.
- そこから電流が入ってくる、あるいは出ていく(電池のような)電気装置上の接点
- a contact on an electrical device (such as a battery) at which electric current enters or leaves
- 磁場に浮いた可動コイルの中を流れる電流によって加えられた力で動作する検流計
- a galvanometer that is operated by the force exerted by an electric current flowing in a movable coil suspended in a magnetic field
- 固有オン抵抗が小さいほど、所定の定格電流に対する順電圧(VF)降下は小さい。
- The lower the specific on-resistance, the lower the forward voltage (VF) drop is for a given current rating.
- 図4を参照すると、室温で測定する電流密度対逆バイアス電圧特性が示されている。
- Referring to figure 4, the measured room temperature current density vs reverse bias voltage characteristic are shown.
- 私は一度思いもかけずライデン電池の放電流が体内を通り抜けたことがありますが、
- I once had the discharge of a large Leyden battery passed unexpectedly through me:
- この衝突イオン化は、他のプロセスによって生成される電流を 効果的に増加する。
- This impact ionisation effectively multiplies the currents produced by the other processes.
- 高キャリア濃度の結果として、熱発生レートが高くなり、暗リーク電流が高くなる。
- A consequence of a high carrier density is a high thermal generation rate, which leads to high dark leakage currents.
- (電気)通常の電気の状態(あるいはそんな過渡電流の一連)での激しい過渡電流波
- a sharp transient wave in the normal electrical state (or a series of such transients)
- 商用周波数の2倍+1Hzの交流電圧を重畳した時の1Hzの周波数成分を持った電流
- AC superposition
- また、温度の低下は、式(1)によれば空乏領域に関連するリーク電流を 削減する。
- A reduced temperature also reduces the leakage current associated with the depletion region according to equation (1).
- 電子機器用コネクタ−試験及び測定−第5−1部:電流容量試験−試験5a:温度上昇
- Connectors for electronic equipment - Tests and measurements - Part 5-1: Current-carrying capacity tests - Test 5a: Temperature rise
- 超電導−給電装置−超電導機器へ給電する電流リードの特性試験に関する一般要求事項
- Superconductivity-Superconducting power devices-General requirements for characteristic tests of current leads designed for powering superconducting devices
- 2つのコイル間の電磁場の相互作用を用いて電流、電圧、あるいは電力を測定する計器
- measuring instrument that uses the interaction of the magnetic fields of two coils to measure current or voltage or power
- このように、不 完全なダイオードでは通常、熱発生によってリーク電流が発生する。
- Thermal generation thus leads to leakage current in the normal manner of an imperfect diode.
- リーク電流は、活性ゾーンの残留熱と光発生のような、 多くのソースから発生する。
- The leakage current arises from many sources, such as residual thermal and optical generation in the active zone.
- 第1の回路を通して流れる電流が第2の回路の電流を入れたり切ったりできる電気装置
- electrical device such that current flowing through it in one circuit can switch on and off a current in a second circuit
- 配線系統において、電気装置を動かすための電流を取り込む部分を備え付けた差し込み口
- receptacle providing a place in a wiring system where current can be taken to run electrical devices
- 抽出界面では、少数キャリア濃度が十分には低くないために、リーク電流が存在し得る。
- At the extracting interface there can be current leakage because the minority carrier concentration is not low enough.
- このような順電圧降下の負の温度係数は、接合温度の増加のため、導通電流を増加させる。
- Such a negative temperature coefficient for the forward voltage drop may increase the conducting current, due to the increase in the junction temperature.
- ファインセラミックス−電流遮断法による固体酸化物形電気化学セルの単セル分極測定方法
- Fine ceramics (advanced ceramics,advanced technical ceramics)- Single cell polarization test method for solid oxide electrochemical cell by current interruption technique
- アルミニウム及びアルミニウム合金の陽極酸化皮膜厚さ試験方法−第2部:渦電流式測定法
- Test methods for thickness of anodic oxide coatings on aluminum and aluminum alloys−Part 2 : Eddy current method
- 熱した鉄、電流または腐食剤を使用することで(組織)を燃やす、焦がす、または凍らせる
- burn, sear, or freeze (tissue) using a hot iron or electric current or a caustic agent
- 電流が体を通過することによる外傷性傷害(高圧線との接触や雷に打たれるというような)
- trauma caused by the passage of electric current through the body (as from contact with high voltage lines or being struck by lightning)
- (抵抗よりはむしろ)インダクタンスとキャパシタンスから起こる電流の流れに対する抵抗
- opposition to the flow of electric current resulting from inductance and capacitance (rather than resistance)
- 電気回路の一部を形成するコイルで、回路内の電流変化が隣接している回路の電流を誘導する
- coil forming the part of an electrical circuit such that changing current in it induces a current in a neighboring circuit
- サイリスタは、過渡電流、つまりdi/dt及びdv/dt能力が非常に高いデバイスである。
- A thyristor is a highly rugged device in terms of transient currents, di/dt and dv/dt capability.
- 結果として、負荷電流は、BTOのアノード100aからGTOのゲート110gに転流する。
- As a result, the load current is commutated from the BTO anode 100a to the GTO gate HOg.
- 電流が水銀蒸気を通り抜けると、薄青い強い光(紫外線放射を多く含む)を発する紫外線ランプ
- ultraviolet lamp that emits a strong bluish light (rich in ultraviolet radiation) as electric current passes through mercury vapor
- 回路の電流または電圧が、振幅の約63%まで指数関数的に上昇または下降するのにかかる時間
- the time required for the current or voltage in a circuit to rise or fall exponentially through approximately 63 per cent of its amplitude
- 変調が由来する源に関するコード化された情報を意味する電気量(電圧、電流または磁場強度)
- an electric quantity (voltage or current or field strength) whose modulation represents coded information about the source from which it comes
- 電子機器用コネクタ−試験及び測定−第5−2部:電流容量試験−試験5b:電流・温度の軽減
- Connectors for electronic equipment - Tests and measurements - Part 5-2: Current-carrying capacity tests - Test 5b: Current-temperature derating
- 連続射撃または電流を使って、あるいは使ったかのようにして、あるいは、銃殺のようにして殺す
- kill with or as if with a burst of gunfire or electric current or as if by shooting
- AC回路での電力の単位で、1ボルトが1アンペアの電流を生み出すときに放散される電力と同じ
- a unit of electrical power in an AC circuit equal to the power dissipated when 1 volt produces a current of 1 ampere
- 実効抵抗が横電場によってコントロールできるチャンネルに、大部分の電流が流れるトランジスタ
- a transistor in which most current flows in a channel whose effective resistance can be controlled by a transverse electric field
- 低抵抗・高インダクタンスのコイルで電子回路で直流電流を通し交流電流を薄めるのに用いられる
- a coil of low resistance and high inductance used in electrical circuits to pass direct current and attenuate alternating current
- V1 310は、SiC BJT105に加えられるベース電流IBを調節するようにも構成される。
- Vl 310 is also configured to regulate the base current IB that is applied to the SiC BJT 105.
- V2 320は、SiC GTO110に加えられるゲート電流IGを調節するようにも構成される。
- V2 320 is also configured to regulate the gate current I0 that is applied to the SiC GTO 110.
- イオンを偏向させ薄い割れ目に入れて、電位計でイオン電流を測定することでスペクトルを得る分光器
- spectroscope for obtaining a mass spectrum by deflecting ions into a thin slit and measuring the ion current with an electrometer
- 特に、ゲートとカソードとの間に短い電流パルスを印加することにより、サイリスタはターンオンする。
- More particularly, a thyristor may be turned on by applying a short current pulse across the gate and the cathode.
- 次に、式(1)等を、達成しうる接合部で発生する電流の削減を計算するために使用することが出来る。
- Equation (1) or similar can then be used to calculate the reduction in the junction generated currents which can be achieved.
- 従って、以下に記述するように、この接合部によって発生するリーク電流とl/fノイズが削減される。
- As described below, the leakage current and 1/f noise generated by the junction are therefore reduced.
- 外因性状況で、許容レベルのリーク電流で 動作させるために、これらの装置は、一般的に冷却される。
- To obtain operation in the extrinsic regime, but with an acceptable level of leakage current, these devices are generally cooled.
- 電磁両立性−第3−2部:限度値−高調波電流発生限度値(1相当たりの入力電流が20A以下の機器)
- Electromagnetic compatibility (EMC)-Part 3-2: Limits-Limits for harmonic current emissions (equipment input current < 20 A per phase)
- また、これに関連して、得られる誘電体膜のリーク電流密度も約1.0E-01A/cm2と非常に低い。
- The associated leakage current densities of the resulting dielectric films are also very low, on the order of 1.OE-01 A/cm2.
- 電気エネルギーの単位で、1アンペアの電流が1秒間1オームの抵抗を通過した時になされる仕事量と同じ
- a unit of electrical energy equal to the work done when a current of one ampere passes through a resistance of one ohm for one second
- 図5及び図6は、本発明のいくつかの実施例によるBTOの電流-電圧(I-V)特性を示すグラフである。
- Figures 5 and 6 are graphs illustrating current-voltage (I- V) characteristics of a BTO according to some embodiments of the present invention.
- 電子機器用コネクタ−試験及び測定−第2−2部:導通及び接触抵抗試験−試験2b:接触抵抗−規定電流法
- Connectors for electrical equipment-Tests and measurements-Part2-2:Electrical continuity and contact resistance-Test 2b:Contact resistance-Specified test method
- また、これに関連して、得られる誘電体膜のリーク電流密度も約 1.0E-01A/cm2と非常に低い。
- The associated leakage current densities of the resulting dielectric films are also very low, on the order of 1.OE-01 A/cm2.
- 高周波誘導部品−電気的特性及び測定方法−第2部:DC/DCコンバータ用インダクタの定格電流の決め方
- High frequency inductive components-Electrical characteristics and measuring methods-Part 2: Rated current of inductors for DC to DC converters
- インダクタンスの単位で、毎秒1アンペアの割合で電流が変化するとき1ボルトの誘導された起電力を生じる
- a unit of inductance in which an induced electromotive force of one volt is produced when the current is varied at the rate of one ampere per second
- 定格最大電流密度が三〇〇アンペア毎平方ミリメートルを超えるもの又は定格磁束密度が八テスラを超えるもの
- Superconducting magnets with a rated maximum current density exceeding 300 amperes per square millimeter or with a rated magnetic flux density exceeding 8 teslas
- 超電導−臨界電流の試験方法−銀シースビスマス2212及びビスマス2223酸化物超電導線の直流臨界電流
- Superconductivity-Part 3:Critical current measurement-DC critical current of Ag- and/or Ag alloy-sheathed Bi-2212 and Bi-2223 oxide superconductors
- この値を上回ると、SiC BJT Q1 105は線形領域での動作に入り、定電流源として動作を開始する。
- When this value is exceeded, SiC BJT Ql 105 enters its linear region and begins to behave as a constant current source.
- 電流を運ぶ銅線が、その近くで鉄か鉄鋼の断片を磁化させることができると観測されたとき、電磁気が発見された
- electromagnetism was discovered when it was observed that a copper wire carrying an electric current can magnetize pieces of iron or steel near it
- 表示線リレー。事故電流を通信線(パイロットワイア)を利用して相手端子に送り、自端電流との差を判定する。
- PWR(PW) Pilot Wire Relay
- 起電力の割合で、回路で、それを生じる電流の変化の割合に対する自己誘導によって生じるもので、単位はヘンリー
- the ratio of the electromotive force produced in a circuit by self-induction to the rate of change of current producing it, expressed in henries
- 接合部からの暗電流の減少に加えて、本発明は、赤外線 光ダイオードの低周波(即ち、l/f)ノイズも削減する。
- In addition to a reduction in dark currents from the junction, the present invention also reduces low frequency (or 1/f) noise in infrared photo-diodes.
- 全てのこれらのケースでは、接合部で発生した電流は空乏領域でのバンドギャップの増加に従って急速に減少す る。
- In all these cases, the junction generated currents decrease rapidly with increasing band gap in the depletion region.
- ガルバニ電流の使用により金属で覆うこと、または、鉄の腐食を防ぐため亜鉛で鉄をコーティングすることのどちらか
- either the work of covering with metal by the use of a galvanic current or the coating of iron with zinc to protect it from rusting
- 高効率デュアル層接触領域を設けることによって、排除界面と抽出界面と関連するリーク電流を実質的に減少させる。
- The provision of high efficiency dual layer contact zones substantially reduces the leakage currents associated with the excluding and extracting interfaces.
- SiC GTO110の負の温度係数のため、従来のSiC GTOでの並列配列では、静的な電流分担が困難である。
- The negative temperature coefficient of the SiC GTO 110 may make static current sharing difficult in parallel arrays of conventional SiC GTOs.
- 皮膚の電気抵抗を記録することにより、あるいは身体で発生する弱い電流を記録することにより測定されることができる
- can be measured either by recording the electrical resistance of the skin or by recording weak currents generated by the body
- 電流が誘導回路で断ち切られたら(スパーク)を抑圧するか、またはコンポーネントか装置で(振動か放出)を抑圧する
- suppress (sparking) when the current is cut off in an inductive circuit, or suppress (an oscillation or discharge) in a component or device
- 制御装置の構造若しくは回路又は定電流回路の変更(灯質、光度その他灯火の光学的特性に影響を与える場合に限る。)
- Alteration of the structure or circuits of control unit or of constant current circuits (limited to such a case where the circuits may affect the light quality, intensity, or other optical properties of lights)
- それらの間の1ボルトの電位差が1アンペアの電流を生み出す際の導体における二点間での抵抗と同等の電気抵抗の単位
- a unit of electrical resistance equal to the resistance between two points on a conductor when a potential difference of one volt between them produces a current of one ampere
- これにより、BTO100は導通状態となり、アノード端子100aとカソード端子100cとの間に負荷電流が流れる。
- This puts the BTO 100 in the conducting state, and a load current flows between the anode terminal 100a and the cathode terminal 100c.
- トリガー火花間げきであって、陽極遅延時間が一五マイクロ秒以下のもののうち、せん頭電流が五〇〇アンペア以上のもの
- Among trigger spark gaps with a cathode delay time of 15 microseconds or less, those with a peak current of 500 amperes or more
- しかしながら、発生、表面効果、トンネリング及び衝突イオン化のような他の空乏領域効果のためにリーク電流がなお存在する。
- However, a leakage current is still present because of other depletion region effects such as generation, surface effects, tunnelling and impact ionization
- 熱発生レートは、文献 EP0167305のオージェ抑制装置において大きく削減されるが、残留リーク電流がなお存在する。
- Although thermal generation rates are greatly reduced in the Auger suppressed device of EP0167305, a residual leakage current is still present.
- サイリスタは、そのゲート端子に電流パルスを受けると、そのアノード端子とカソード端子との間に電流を通すように動作する。
- A thyristor may be activated to conduct current between its anode and cathode terminals when a current pulse is received at its gate terminal.
- したがって、サイリスタは、大電流を制御又は通し、高電圧を効果的に遮断することができる(すなわち、電圧スイッチである)。
- Therefore, the thyristor can control or pass large amounts of current and effectively block high voltages (i.e., a voltage switch).
- 従って、リーク電流とl/fノイズの両方はp-n接合 部のバンドギャップを増加させることによって削減されることが出来る。
- Hence, both the leakage current and 1/f noise can be reduced by increasing the band gap at the p-n junction.
- さらに、図3を参照すると、本発明のいくつかの実施例によるBTO100を含む制御回路300は、故障電流制限機能を提供する。
- Still referring to Figure 3, the control circuit 300 including the BTO 100 according to some embodiments of the present invention provides a fault current limiting feature.
- 特に、SiC BJT Q1 105により与えられるコレクタ電流ICは、そのベース電流IBと電流利得βとの積の値で定まる。
- More particularly, the collector current Ic provided by SiC BJT Ql 105 may be determined by the product of its base current IB and its current gain β.
- 本発明のいくつかの実施例によるバイポーラ・パワー・スイッチング・デバイスは、飽和電流の負の温度係数も提供することができる。
- Bipolar power switching devices according to some embodiments of the present invention may also provide a negative temperature coefficient for the saturation current.
- 英国の化学者、物理学者で、パラジウムとロジウムを発見し、静電気と電流が同じものであることを示した(1766年−1828年)
- English chemist and physicist who discovered palladium and rhodium and demonstrated that static and current electricity are the same (1766-1828)
- 2ポイントの間で消散するパワーが1ワットであるときに1アンペアの電流を運ぶ導体の2ポイントの間の電位差と等しい可能性の単位
- a unit of potential equal to the potential difference between two points on a conductor carrying a current of 1 ampere when the power dissipated between the two points is 1 watt
- 注)装置は、燃焼時間等のいくつかの制限の範囲内で、括弧で示されたパラメータのもとで、プラズマ電流17 MAまでの能力がある。
- Note: The machine is capable of plasma current up to 17 MA, with the parameters shown in parentheses, within some limitations on other parameters such as pulse length.
- 電子管に使用するように設計した含浸形陰極であって、定格動作状態での連続放射電流密度が五アンペア毎平方センチメートルを超えるもの
- Impregnated cathodes designed for use in electron tubes with continuous emission current density under rated operating conditions exceeding 5 amperes per square centimeter
- 通常、サイリスタの固有オン抵抗は、サイリスタに印加された所定の電圧で単位面積当たりの電流を大きくできるようにできるだけ小さくする。
- The specific on-resistance for a thyristor is typically as small as possible so as to provide a large current per unit area for a given voltage applied to the thyristor.
- 外部磁場によって、引き起こされた電流がそれらを通りゼロ起電力を有する時、コイルは配置されるゼロ合成外部磁場を与えるように配置される
- the coils are arranged to give zero resultant external magnetic field when a current passes through them and to have zero electromotive force induced in them by an external magnetic field
- 7大プロジェクトに加えて、燃料、排気、トリチウムプロセス、加熱電流駆動、電源、プラズマ計測及び安全性に関するR&Dが大きく進展した。
- In addition to the seven large R&D projects, development of components for fueling, pumping, tritium processing, heating/current drive, power supplies, plasma diagnostics as well as safety related R&D have significantly progressed.
- 測定,制御及び研究室用電気機器の安全性—第2−32部:電気的測定及び試験のための手持形及び手で操作する電流センサに対する個別要求事項
- Safety requirements for electrical equipment for measurement, control, and laboratory use-Part 2-32: Particular requirements for hand-held and hand-manipulated current sensors for electrical test and measurement
- 医学的な理由(いぼの摘出など)から、組織を熱した鉄、電流、または腐食薬で焼いて、または凍らせて破壊するために使用する、器具または物質
- an instrument or substance used to destroy tissue for medical reasons (eg removal of a wart) by burning it with a hot iron or an electric current or a caustic or by freezing it
- 電流飽和能力は、このようなデバイスを、ターンオン中の突入電流及び/又は短絡事故の場合の電流オーバー・シュートから保護することができる。
- The current saturation capability can protect such devices from inrush current during turning-on, and/or current over shooting in the case of short-circuit failure.
- この条件が一旦満足されなくなると、SiC BJT105は、活性領域に入り、その電流を、ベース電流IBと電流利得βとの積の値に制限する。
- Once this criterion is no longer met, the SiC BJT 105 enters its active region and limits the current to the product of the base current IB and current gain β.
- この動作により、SiC GTO110のゲート110gには、抵抗R1 405の抵抗値で制限されたゲート電流IGで、順方向バイアスをかける。
- This action forward biases the gate HOg of the SiC GTO HOJ with the gate current IG limited by the resistance of resistor Rl 405.
- バイポーラ・パワー・トランジスタは、非導通状態と、第一及び第二主端子間に電流を流すことができる導通状態との間を切り替えるように構成される。
- The bipolar power transistor is configured to switch between a nonconducting state and a conducting state that allows current flow between the first and second main terminals.
- しかしながら、本発明は、任意のタイプのダイオード構造においてp-n(又はn-p)接合部の リーク電流を削減するために使用することが出来る。
- However, the invention can be used to reduce the leakage current at a p-n (or n-p) junction in any type of diode structure.
- スパッタリング法を用いるものであって、毎時一五マイクロメートル以上の溶着速度における電流密度が一〇ミリアンペア毎平方センチメートル以上のもの
- Coating devices that use the sputtering method and has a current density of 10 milliamperes per square centimeter or more for hourly deposition rates of 15 micrometers or more
- 基準の量は、長さ(メートル)、量(キログラム)、時間(秒)、電流(アンペア)、温度(ケルヴィン)、物質の量(モル)、光の強度(カンデラ)である
- fundamental quantities are length (meter) and mass (kilogram) and time (second) and electric current (ampere) and temperature (kelvin) and amount of matter (mole) and luminous intensity (candela)
- 図4に示した本発明の実施例も、万一負荷電流が予め定められたレベルを上回るという場合には、SiC GTO110をターンオフする過電流特性を提供する。
- Embodiments of the present invention as illustrated in Figure 4 may also provide an over current feature that turns off the SiC GTO 110 in the event that the load current exceeds a predetermined value.
- したがって、負荷電流は、アノード端子100aからSiC GTO110のゲート110gに転流することによりSiC GTO110を急速にターンオフする。
- Accordingly, the load current is commutated from the anode terminal 100a into the gate HOg of the SiC GTO 110, causing the SiC GTO 110 to be rapidly turned off.
- 同様に、ベース105bへの制御信号の印加により、SiC BJT105をターンオンして、コレクタ端子105cとエミッタ端子105eとの間に電流を通す。
- Likewise, application of a control signal to the base 105b causes the SiC BJT 105 to turn on, conducting current between the collector 105c and emitter 105e terminals.
- 電磁両立性−第4−34部:試験及び測定技術−1相当たりの入力電流が16Aを超える電気機器の電圧ディップ,短時間停電及び電圧変動に対するイミュニティ試験
- Electromagnetic compatibility - Part 4-34:Testing and measurement techniques-Voltage dips, short interruptions and voltage variations immunity tests for equipment with input current more than 16 A per phase
- 本発明は、半導体ダイオード装置に関し、より詳細には、赤外線検出器や負発光源として使用されるノイズ低減と暗電流オージェ抑制半導体ダイオード構造に関する。
- This invention relates to a semiconductor diode device, and in particular to a reduced noise and reduced dark current Auger suppressed semiconductor diode structure for use as an infrared detector or as a negative luminescent source.
- ゲートに印加された制御信号により、デバイスを、電流がデバイスのアノードとカソードの間を自由に流れることができる「オン」状態又は導通状態に「ラッチ」する。
- A control signal applied to the gate causes the device to "latch" into an "on" or conductive state, in which current can flow freely between the anode and cathode of the device.
- 安定した電流がながれる2つの支配している電気回路の法則:一点におけるすべての電流の合計は0であり、周辺の密接した電流の電圧利得と電圧降下の合計は0である
- two laws governing electric networks in which steady currents flow: the sum of all the currents at a point is zero and the sum of the voltage gains and drops around any closed circuit is zero
- ビームエネルギーが六五キロ電子ボルト以上、かつ、ビーム電流が四五ミリアンペア以上のものであって、加熱された半導体材料の基板に酸素を注入することができるもの
- Ion implanters with beam energies of 65 kiloelectron volts or more and beam currents of 45 milliamperes or more, that are capable of implanting oxygen on a heated superconductor material substrate
- このリーク電流に対する寄与は、上述のドーピング要求を満足することによって削減することが出来るが、これは、抽出と排除界面 の近くでは、技術的課題でありうる。
- This contribution to the leakage current can be reduced by meeting the doping requirements described above, but this can be technically challenging near the extraction and exclusion interfaces.
- 図6は、本発明のいくつかの実施例によるSiC BTOは、動作温度が上昇すると電流飽和能力を提供することを、線605(室温)及び線610(約200℃)で示す。
- Figure 6 illustrates that a SiC BTO according to some embodiments of the present invention provides current saturation capability as operating temperature increases, as shown by line 605 (room temperature) and line 610 (about 2000C).
- 図4を参照して上記したように、SiC BJT Q1 105は、導通状態の連続全負荷電流をサポートし、遮断状態時には電圧V2’をサポートするように選択される。
- As discussed above with reference to Figure 4, SiC BJT Ql 105 may be selected to support continuous full load current in the conducting state, and to support voltage V2' when in the blocking state.
- また、BJT Q2 425も、導通状態(例えば、SiC GTO110の転流中)の全負荷電流をサポートし、遮断状態時には電圧V2’をサポートするように選択される。
- BJT Q2 425 may also be selected to support full load current in the conducting state (e.g., during the commutation of the SiC GTO 110), and to support voltage V2' when in the blocking state.
- このように、BJT105及びGTO110が、共に導通状態に切り替えられた時に、BTO100のアノード100a端子とカソード100c端子との間に負荷電流が流れる。
- As such, when the BJT 105 and the GTO 110 are both switched to a conducting state, a load current may flow between the anode 100a and cathode 100c terminals of the BTO 100.
- さらに、本発明のいくつかの実施例によるバイポーラ・パワー・スイッチング・デバイスは、SiC BJTが活性領域で動作した時には、電流飽和能力を提供することができる。
- In addition, bipolar power switching devices according to some embodiments of the present invention may provide current saturation capability when the SiC BJT operates in the active region.
- いくつかの実施例において、バイポーラ・パワー・スイッチング・デバイスは、バイポーラ・トランジスタが活性領域で動作させられる時、電流飽和能力を提供するように構成される。
- In some embodiments, the bipolar power switching device may be configured to provide current saturation capability when the bipolar transistor is operated in the active region.
- これにより、BTOのアノード100aからGTOのゲート110gに、強制的に負荷電流を転流させて、SiC GTO110を急速にターンオフさせることにより故障電流を阻止する。
- This forces the load current to commutate from the BTO anode 100a to the GTO gate 11 Og, which rapidly turns off the SiC GTO 110, thereby interrupting the fault current.
- 出力電流が五〇〇アンペア以上のもののうち、電流又は電圧の変動率が〇・一パーセント未満で、かつ、出力電圧が一〇〇ボルト以上の状態で連続八時間を超えて使用することができるもの
- Among direct current power units with an output current of 500 amperes or more, those with a current or voltage fluctuation rate less than 0.1%, and capable of use for exceeding 8 consecutive hours under an output voltage of 100 volts or more
- 特に、ベース105bに印加された制御信号は、例えば、ベース電流IBの変化がコレクタ電流ICにほとんど影響を与えない飽和領域でBJT105を動作させるのに十分なものである。
- In particular, the control signal applied to the base 105b is sufficient to operate the BJT 105 in the saturation region, e.g., where changes in the base current IB have little effect on the collector current Ic.
- 特に、SiC BJT105のコレクタ電流ICが、ベース電流IBとSiC BJT105の電流利得βとの積を下回っている間は、SiC BJT105は強力な飽和状態を維持する。
- In particular, the SiC BJT 105 remains in hard saturation so long as its collector current Ic is below the product of the base current IB and the current gain β of the SiC BJT 105.
- 出力電圧が二〇、〇〇〇ボルト以上のもののうち、電流又は電圧の変動率が〇・一パーセント未満で、かつ、出力電流が一アンペア以上の状態で連続八時間を超えて使用することができるもの
- Among direct current power units with an output voltage of 20,000 volts or more, those with a current or voltage fluctuation rate less than 0.1%, and capable of use for exceeding 8 consecutive hours with an output current of 1 ampere or more
- この時間中、NMOSトランジスタ404のドレーン電流を、SiC GTOのゲート110gを駆動するのに適切なレベルに制限するように、NMOSトランジスタ404にバイアスをかける。
- During this time, NMOS transistor 404 may be biased in such a way to limit its drain current to a level appropriate to drive the SiC GTO gate HOg.
- ITRS(半導体技術国際ロードマップ)規定によると、100nmテクノロジーノードには、ゲート誘電体のEOT厚は10Åで、リーク電流密度は 1.0A/cm2未満である必要がある。
- The ITRS (International Technology Roadmap for Semiconductors) specifications demand that, for the lOOnm technology node the gate dielectric EOT shall be 10 A thick with leakage current density less than 1.0 A cm2.
- また、ツェナー・ダイオード及び/又は直列接続された数個のパワー・ダイオードを含むバイパス段を用いて、アノード電流をサイリスタのゲート端子に逃がすと、サイリスタはターンオフする。
- Also, a bypass stage including a zener diode and/or several power diodes connected in series may be used to divert anode current to the thyristor gate terminal to turn off the thyristor.
- 図3は、RT-NO酸化(i)及び新規の紫外線酸化工程(ii)によって酸窒化 膜層が形成された誘電体膜において、リーク電流密度(A/cm2)をEOT(Å)に対してプロットしている。
- In FIG. 3, leakage current density (in A/cm2) is plotted against EOT (in A) of the dielectric films in which the oxynitride layers are formed by (i) RT-NO oxidation and (ii) the novel UV-oxidation process.
- 超電導ゲートを有するデジタル回路用の電流スイッチングの機能を有するものであって、ゲート当たりの遅延時間にゲート当たりの電力消費を乗じて得た値が一、〇〇〇億分の一ミリジュール未満のもの
- Devices possessing a current switching function for use in digital circuits with superconducting gates for which the value obtained by multiplying the delay time per gate by the power consumption per gate is less than 1/100 billion milijoules
- 反転ドライバINV402、非反転ドライバBUF403及びNMOSトランジスタ404の出力には、適切な電流制限が設けられ、(全部ではないが)多くの動作条件下で安全に動作することができる。
- Adequate current limiting is provided on the outputs of the inverting driver INV 402, the non-inverting driver BUF 403, and the NMOS transistor 404 to allow safe operation under many (if not all) operating conditions.
- 米国の電気技師で発明者(クロアチア生まれだが、セルビア人の家系)で、交流電流の原則を発見し、最初の交流誘導電動機とテスラコイルと発振器のいくつかの形態を開発した(1856年−1943年)
- United States electrical engineer and inventor (born in Croatia but of Serbian descent) who discovered the principles of alternating currents and developed the first alternating-current induction motor and the Tesla coil and several forms of oscillators (1856-1943)
- 請求項1記載の電子デバイスにおいて、バイポーラ・パワー・スイッチング・デバイスは、バイポーラ・トランジスタが活性領域で動作させられる時、電流飽和能力を提供するように構成される電子デバイス。
- The electronic device of Claim 1, wherein the bipolar power switching device is configured to provide current saturation capability when the bipolar transistor is operated in the active region.
- 特に、ゲート110gへの制御信号の印加により、SiC GTO110を、導電状態又は「オン」状態に「ラッチ」することにより、アノード110aとカソード110cとの間に電流を流すことができる。
- More particularly, application of a control signal to the gate HOg causes the SiC GTO 110 to "latch" into a conductive or "on" state, which allows current flow between the anode HOa and cathode 110c.
- GTO110のゲート110gとBJT105のコレクタ105cとの間の電圧降下がツェナー・ダイオード215の降伏電圧を上回る時には、バイパス段が導通するように構成され、故障電流制限機能を提供する。
- The bypass stage is configured to conduct when the voltage drop between the gate 11 Og of the GTO HO and the collector 105c of the BJT 105 exceeds the breakdown voltage of the zener diode 215 to provide a fault current limiting feature.
- 二つの接触するゾーンは、一般的に、入射放射線に対して実質的に感度 をなくす、より高いバンドギャップを有し、且つより低いバンドギャップ材料で、より容易に生じる、熱発生プロセスからのリーク電流を削減する。
- The two contacting zones generally have higher band-gaps which makes them substantially insensitive to the incident radiation and also reduces leakage current from the thermal generation processes that occur more readily in lower band gap materials.
- したがって、本発明の実施例によるバイポーラ・パワー・スイッチング・デバイスは、温度上昇に伴って順電圧降下が増加し、並列接続されたデバイスの電流分布を更に均一にできるため、より容易に並列接続することができる。
- Accordingly, bipolar power switching devices according to embodiments of the present invention can be more easily paralleled, as the forward voltage drop may increase with increasing temperature to promote more even current distribution in parallel connected devices.
- 前記追加層の前記バンドギャップと層厚が、検出器の量子効率への影響を実質的に有さず、且つ所定の温度で暗リーク電流を大きく削減する伝導帯にバンプを生成する、請求項1から11のいずれか一項に記載の半導体ダイオード。
- A semiconductor diode as claimed in any of the preceding claims wherein the band gap and layer thickness of the additional layer produces a bump in the conduction band which has no substantial effect on the quantum efficiency of the detector and provides a significant reduction in the dark leakage current at a predetermined temperature.
- 当業者に知られているように、サイリスタは、電流フローのためのアノード及びカソード、並びに遮断状態から導通状態に及びその逆にデバイスを切り替えるためのゲートを有する4層からなるラッチ・スイッチング・デバイスである。
- As is known to those skilled in the art, a thyristor is a four-layer latching switching device having an anode and a cathode for current flow and a gate for switching the device from a blocking state to a conducting state, and vice versa.
- 例えば、本発明のいくつかの実施例によるBTOは、SiC BJTを用いて、比較的高速でSiCサイリスタのアノード電流をターンオフすることができるため、従来のSiCサイリスタよりも高速で、ターンオフすることができる。
- For example, a BTO according to some embodiments of the present invention can be turned off faster than conventional SiC thyristors, as the SiC BJT may be used to turn off the anode current of the SiC thyristor at a relatively high rate.
- 更に、追加層のバンドギャップと層厚は、検出器の量子効率への影響を実質的 に有さないが、220Kから300Kの範囲内のような所定の温度で暗リーク電流を大きく削減する伝導帯にバンプを生成するように設計することが出来る。
- Furthermore, the band gap and layer thickness of the additional layer can be designed so as to produce a bump in the conduction band which has no substantial effect on the quantum efficiency of the detector but provides a significant reduction in the dark leakage current at a predetermined temperature, such as within the range 220K to 300K.
- 図4を参照すると、BTO100が導通状態にある時には、負荷電流は、BTO100のアノード端子100aから、SiC BJT Q1 105及びSiC GTO 110を経由して、BTO100のカソード端子100cに流れる。
- Referring now to Figure 4, when the BTO 100 is in the conducting state, a load current flows from the anode terminal 100a of the BTO 100, through SiC BJT Ql 105 and the SiC GTO 110, and to the cathode terminal 100c of the BTO 100.
- サイリスタ、ハイパワー・バイポーラ接合トランジスタ(HPBJT)、パワー金属酸化物半導体電界効果トランジスタ(MOSFET)等のパワー半導体デバイスは、大電流を制御又は通し、及び高電圧を遮断できる半導体デバイスである。
- Power semiconductor devices, such as thyristors, high-power bipolar junction transistors ("HPBJT"), or power metal oxide semiconductor field effect transistors ("MOSFET"), are semiconductor devices capable of controlling or passing large amounts of current and blocking high voltages.
- 転流バイポーラ・トランジスタは、ツェナー・ダイオードの導通に応答して、導通状態に切り替えられ、サイリスタのゲート端子に負荷電流を与えてバイポーラ・パワー・スイッチング・デバイスを非導通状態に切り替えるように構成される。
- The commutating bipolar transistor may be configured to be switched to a conducting state responsive to conduction of the zener diode to provide the load current to the gate terminal of the thyristor and switch the bipolar power switching device to the nonconducting state.
- 制御回路は、さらに、バイポーラ・トランジスタのコレクタ端子にサイリスタのゲート端子を結合して、負荷電流をサイリスタのゲート端子に転流し、バイポーラ・パワー・スイッチング・デバイスを非導通状態に切り替えるように構成される。
- The control circuit may be further configured to couple the gate terminal of the thyristor to the collector terminal of the bipolar transistor such that the load current is commutated to the gate terminal of the thyristor to switch the bipolar power switching device to the nonconducting state.
- 図3は、(i)紫外線酸化によって酸窒化膜層を形成する場合、及び、(ii)従来の急速加熱処理によって酸窒化膜層を形成する場合に、形成されたゲートスタック誘電体膜のリーク電流密度と実効酸化膜厚(EOT)とを対比したグラフである。
- FIG. 3 is a graph comparing leakage current density with equivalent oxide thickness (EOT) for the gate stack dielectric films formed (i) when UV-oxidation is used to apply the oxynitride layer and (ii) when conventional rapid thermal processing is used to apply the oxynitride layer.
- 更に、ドーピングとバンド ギャップが共に急速に変化すると、バンドエッジのレベルでの、他の場合は正常な、スイッチの一時的中断を起こす可能性があり(「グリッチ」(誤った電気信 号)と呼ばれる)、装置における電流の適切な流れを妨げる。
- Additionally, co-located rapid changes of doping and bandgap can give rise to temporary interruptions in the otherwise regular switches in the level of the band edges (termed "glitches") and may impede the proper flow of current in the device.
- これにより、電流は、DC電圧源V2’420から、NMOSトランジスタ404を経由し、抵抗R1 405に流れ、SiC GTO110のゲート110gに入り、SiC GTO110のアノード110aを経由し、DC電圧源V2’420に戻る。
- This causes current to flow from DC voltage source V2' 420 through NMOS transistor 404, to resistor Rl 405, into the gate HOg of the SiC GTO 110, through the anode HOa of the SiC GTO 110, and back to DC voltage source V2' 420.
- 故障電流が増加すると、SicBJT Q1 105のコレクタ・エミッタ間電圧VCEはさらに増加することにより、SiC GTO110のアノード・ゲート間接合に逆バイアスをかけ、SiC GTO110をターオンオフし、負荷電流を遮断する。
- As the fault current increases, the collector-to-emitter voltage VCE across SiC BJT Ql 105 will further increase, thereby reverse biasing the anode-to-gate junction of the SiC GTO 110 and causing the SiC GTO 110 to turn off, interrupting the load current.
- 負荷電流は、BTO100のアノード端子100aとSiC BJT Q1 105のコレクタ105cに入ってエミッタ105eから出て、SiC GTO110のアノード110aに入ってカソード110cとBTO100のカソード端子100cから出る。
- The load current flows into the anode terminal 100a of the BTO 100, into the collector 105c and out of the emitter 105e of SiC BJT Ql 105, into the anode 110a and out of the cathode HOc of the SiC GTO 110, and out of the cathode terminal 100c of the BTO 100.
- バイパス段は、それらの間に電流を通し、バイポーラ・トランジスタのコレクタ端子とサイリスタのカソード端子との間の電流が予め定められたレベルを上回る時には、バイポーラ・パワー・スイッチング・デバイスを非導通状態に切り替えるように構成される。
- The bypass stage may be configured to conduct current therebetween to switch the bipolar power switching device to the nonconducting state when the current between the collector terminal of the bipolar transistor and the cathode terminal of the thyristor exceeds a predetermined level.
- 同様の電流レベルが、ベース105bとゲート110gに与えられ、BJT105とGTO110をそれぞれ導通状態とするため、制御回路を用いて、制御信号を生成し、BJT105のベース105bとGTO110のゲート110gの両方に制御信号を供給する。
- As similar current levels may be provided to the base 105b and the gate HOg to activate the BJT 105 and the GTO 110 to a conducting state, respectively, a control circuit may be used to generate and supply the control signals to both the base 105b of the BJT 105 and the gate llOg of the GTO 110.
- (全部ではないが)多くの負荷電流条件下で、(SiC BJT Q1 105が導通している時に)SiC GTO 110をターンオンするために、電圧源V2’420により与えられる電圧の大きさとNMOSトランジスタ404の電流源能力は、十分な大きさである。
- The magnitude of the voltage provided by voltage source V2' 420 and the current capability of the NMOS transistor 404 are sufficient to turn on the SiC GTO 110 (when SiC BJT Ql 105 is conducting) under many (if not all) load current conditions.
- 四段階ゲートスタック工程の第一段階として紫 外線酸化を行うことによって、四段階ゲートの第一段階としてRT-NO酸化を行うことによって形成された誘電体膜より、EOT値が(14.2Åと)小さ く、かつ、リーク電流密度が低い誘電体膜が得られることは明らかである。
- It is clear that UV-oxidation as the first step in the 4-step gate stack process produces dielectric films that have both lower EOT values (as low as 14.2 A) and lower leakage current densities than dielectric films formed by using RT-NO oxidation as the first step in the 4-step gate stack process.
- ベース端子105b及びゲート端子110gへのそれぞれの制御信号の印加により、BTO100を、(アノード100aとカソード100bとの間に電流が流れない)非導通状態から(アノード100aとカソード100cとの間に電流を流すことができる)導通状態に切り替える。
- Application of respective control signals to the base 105b and the gate HOg terminals switches the BTO 100 from a nonconducting state (where current does not flow between the anode 100a and cathode 100b) to a conducting state (which allows current flow between the anode 100a and cathode 100c).
- バイポーラ・パワー・スイッチング・デバイスは、非導通状態と、BJTのベース端子への第一制御信号の印加とGTOのゲート端子への第二制御信号の印加とに応答してBJTのコレクタとGTOのカソードとの間に電流を流すことができる導通状態との間を切り替えるように構成される。
- The bipolar power switching device is configured to switch between a nonconducting state and a conducting state that allows current flow between the collector of the BJT and the cathode of the GTO responsive to application of a first control signal to the base terminal of the BJT and responsive to application of a second control signal to the gate terminal of the GTO.
- 二次電池であって、五時間率電流での放電及び充電を七五回繰り返した後、電圧が放電を開始する直前の電圧の七五パーセントになるまで五時間率放電電流で放電を行った場合におけるエネルギー密度が零下二〇度以上六〇度以下のすべての温度範囲において一五〇ワット時毎キログラムを超えるもの
- Secondary batteries, that when the voltage is discharged to 75% of the voltage immediately prior to the start of discharge at a 5-hour discharge current rate, after 75 charge/discharge cycles at a 5-hour discharge current rate, has an energy density exceeding 150 watts hours per kilogram at all temperatures in a range from -20 degrees centigrade or more to 60 degrees centigrade or less
- したがって、SiC BJT Q1 105を、SiC GTO110に直列接続して用いることにより、GTO100は非負(例えば、ゼロに近い又は正さえも)の温度係数を持つことができるため、電流分布をより平坦にし、本発明のいくつかの実施例によるBTOを並列接続することを容易にする。
- Accordingly, by employing the SiC BJT Ql 105 in series with the SiC GTO 110, the BTO 100 may have a non-negative (e.g., near-zero or even positive) temperature coefficient, which may promote more even current distribution and ease in paralleling BTOs according to some embodiments of the present invention.
- (全部ではないが)多くのコレクタ電流条件下で、SiC BJT Q1 105及びBJT Q2 425のエミッタをアノード電位まで引き上げるために、電圧源V1’410により与えられる電圧の大きさと反転ドライバINV402及び非反転ドライバBUF403の電流源能力は、十分な大きさである。
- The magnitude of the voltage provided by voltage source Vl' 410 and the current sourcing capability of the inverting driver INV 402 and non-inverting driver BUF 403 are sufficient to pull the emitters of SiC BJT Ql 105 and BJT Q2 425 to anode potential under many (if not all) collector current conditions.
- しかし昨今ではVVVFインバータ制御の採用による誘導電動機の導入や、純電気ブレーキの実用化により高速域からのブレーキ面で、付随客車に機械式ブレーキや渦電流ブレーキなど力行時に不要な機器を搭載する動力集中方式に対する優位性が生じつつある(新世代のTGVやICEも動力分散方式に移行している事例がある)。
- However, nowadays, induction motors employing VVVF inverter control have been introduced in addition to the practical use of regenerative brakes, and this system has become advantageous in the aspect of applying brakes in high-speed operation, compared with the concentrated traction system, because in the latter system, mechanical or eddy-current brakes, not used for moving the train, must be provided on each of the attached, non-powered passenger cars (the distributed traction system has become used in some train-cars of the new-generation TGV and ICE).
- ワイド・バンドギャップ・バイポーラ・パワー・スイッチング・デバイスは、非導通状態と、バイポーラ・トランジスタのベース端子への第一制御信号の印加及びサイリスタのゲート端子への第二制御信号の印加に応答してバイポーラ・トランジスタのコレクタ端子とサイリスタのカソード端子との間に電流を流すことができる導通状態との間を切り替えるように構成される。
- The wide bandgap bipolar power switching device is configured to switch between a nonconducting state and a conducting state that allows current flow between the collector terminal of the bipolar transistor and the cathode terminal of the thyristor responsive to application of a first control signal to the base terminal of the bipolar transistor and responsive to application of a second control signal to the gate terminal of the thyristor.
- いくつかの実施例において、電子デバイスは、第一及び第二制御信号を生成して、サイリスタのゲート端子に第一制御信号を供給し、バイポーラ・トランジスタのベース端子に第二制御信号を供給し、バイポーラ・トランジスタのコレクタ端子とサイリスタのカソード端子との間に負荷電流が流れるような導通状態にバイポーラ・パワー・スイッチング・デバイスを切り替えるように構成される制御回路を、さらに含む。
- In some embodiments, the electronic device may further include a control circuit configured to generate the first and second control signals, supply the first control signal to the gate terminal of the thyristor, and supply the second control signal to the base terminal of the bipolar transistor to switch the bipolar power switching device to the conducting state such that a load current flows between the collector terminal of the bipolar transistor and the cathode terminal of the thyristor.
- 人件費に加えて、建設期間中に幾つかのR&Dが未だ必要となるだろう。例えば、全ての加熱電流駆動方式のR&Dは高い優先順位のもとで実施する必要がある。EDAはITERを実施するための設計上の原則に資するものであるが、コンポーネントの製作過程での、工程の改善や設計の変更、あるいは予期せぬ困難さのために、新たな試験が要求されるかもしれない。従って、建設期間中そのための経費として60-80 kIUAを 計上している。
- In addition to personnel costs, some R&D during construction will still be necessary. For instance, R&D for all heating and current drive methods is required with high priority. Although the EDA has provided the principle qualification of design solutions to be implemented in ITER, during the manufacturing of components, proposed process improvements and design changes or unexpected difficulties could require new tests. It is therefore prudent to expect a spending in R&D of 60-80 kIUA during ITER construction.
- 請求項2記載の電子デバイスにおいて、制御回路は、さらに、サイリスタのゲート端子とバイポーラ・トランジスタのコレクタ端子との間に結合され、バイポーラ・トランジスタのコレクタ端子とサイリスタのカソード端子との間の電流が予め定められたレベルを上回る時には、サイリスタのゲート端子とバイポーラ・トランジスタのコレクタ端子との間に電流を通し、バイポーラ・パワー・スイッチング・デバイスを非導通状態に切り替えるように構成されるバイパス段を含む電子デバイス。
- The electronic device of Claim 2, wherein the control circuit further comprises: a bypass stage coupled between the gate terminal of the thyristor and the collector terminal of the bipolar transistor and configured to conduct current therebetween to switch the bipolar power switching device to the nonconducting state when the current between the collector terminal of the bipolar transistor and the cathode terminal of the thyristor exceeds a predetermined level.
- 事業者は、高圧又は特別高圧の電路の断路器、線路開閉器等の開閉器で、負荷電流をしや断するためのものでないものを開路するときは、当該開閉器の誤操作を防止するため、当該電路が無負荷であることを示すためのパイロツトランプ、当該電路の系統を判別するためのタブレツト等により、当該操作を行なう労働者に当該電路が無負荷であることを確認させなければならない。ただし、当該開閉器に、当該電路が無負荷でなければ開路することができない緊錠装置を設けるときは、この限りでない。
- The employer shall, when opening a switch such as a disconnector and line switch for high voltage or extra-high voltage electrical circuit that is not for breaking load current, in order to prevent an operational error of the said switch, have workers engaged in the said operation confirm that the said electric circuit is on no load using a pilot lamp indicating that such electric circuit is on no load, a tablet for identifying the said electrical circuit, etc. However, this shall not apply to when a locking device is provided for the said switch not to allow circuit opening unless the said electrical circuit is not load.
- 特に、制御回路400は、絶縁ターンオン/オフ信号を与える光トリガ・ドライバ401(光発光ダイオードその他の光源401a及び反転ドライバ401bを含む)と、反転ドライバINV402及び非反転ドライバBUF403と、SiC GTO 110にターンオン・ゲート電流を与える低電圧n型金属酸化物半導体(NMOS)トランジスタ404及び抵抗R1 405と、転流及び故障状態中にSiC GTOのゲート110gをクランプするために用いるバイパス段(BJT Q2 425及びツェナー・ダイオードD1 415を含む)とを含む。
- In particular, the control circuit 400 includes an optically triggered driver 401 (including a light emitting diode or other light source 401a and an inverting driver 401b) to provide an isolated turn on/turn off signal, an inverting driver INV 402 and a non-inverting driver BUF 403, a low-voltage n-type metal-oxide semiconductor (NMOS) transistor 404 and a resistor Rl 405 to provide turn-on gate current for the SiC GTO 110, and a bypass stage (including BJT Q2 425 and zener diode Dl 415), which is used to clamp the SiC GTO gate llOg during commutation and fault conditions.
- 請求項8記載の電子デバイスであって、バイパス段は、さらに、バイポーラ・トランジスタのコレクタ端子に結合されるコレクタ端子と、サイリスタのゲート端子に結合されるエミッタ端子と、ツェナー・ダイオードに結合されるベース端子とを有する転流バイポーラ・トランジスタを含む電子デバイスにおいて、転流バイポーラ・トランジスタは、ツェナー・ダイオードの導通に応答して、導通状態に切り替えられ、サイリスタのゲート端子に負荷電流を与えてバイポーラ・パワー・スイッチング・デバイスを非導通状態に切り替えるように構成される電子デバイス。
- The electronic device of Claim 8, wherein the bypass stage further comprises a commutating bipolar transistor having a collector terminal coupled to the collector terminal of the bipolar transistor, an emitter terminal coupled to the gate terminal of the thyristor, and a base terminal coupled to the zener diode, wherein the commutating bipolar transistor is configured to be switched to a conducting state responsive to conduction of the zener diode to provide the load current to the gate terminal of the thyristor and switch the bipolar power switching device to the nonconducting state.
- 請求項1記載の電子デバイスであって、第一及び第二制御信号を生成して、サイリスタのゲート端子に第一制御信号を供給し、バイポーラ・トランジスタのベース端子に第二制御信号を供給し、バイポーラ・トランジスタのコレクタ端子とサイリスタのカソード端子との間に負荷電流が流れるような導通状態にバイポーラ・パワー・スイッチング・デバイスを切り替えるように構成される制御回路を、さらに備える電子デバイスにおいて、制御回路は、さらに、バイポーラ・トランジスタのコレクタ端子にサイリスタのゲート端子を結合して、負荷電流をサイリスタのゲート端子に転流し、バイポーラ・パワー・スイッチング・デバイスを非導通状態に切り替えるように構成される電子デバイス。
- The electronic device of Claim 1, further comprising: a control circuit configured to generate the first and second control signals, supply the first control signal to the gate terminal of the thyristor, and supply the second control signal to the base terminal of the bipolar transistor to switch the bipolar power switching device to the conducting state such that a load current flows between the collector terminal of the bipolar transistor and the cathode terminal of the thyristor, wherein the control circuit is further configured to couple the gate terminal of the thyristor to the collector terminal of the bipolar transistor such that the load current is commutated to the gate terminal of the thyristor to switch the bipolar power switching device to the nonconducting state.
- 長さ、質量、時間、電流、温度、物質量、光度、角度、立体角、面積、体積、角速度、 角加速度、速さ、加速度、周波数、回転速度、波数、密度、力、力のモーメント、圧力、応力、粘度、動粘度、仕事、工率、質量流量、流量、熱量、熱伝導率、 比熱容量、エントロピー、電気量、電界の強さ、電圧、起電力、静電容量、磁界の強さ、起磁力、磁束密度、磁束、インダクタンス、電気抵抗、電気のコンダク タンス、インピーダンス、電力、無効電力、皮相電力、電力量、無効電力量、皮相電力量、電磁波の減衰量、電磁波の電力密度、放射強度、光束、輝度、照度、 音響パワー、音圧レベル、振動加速度レベル、濃度、中性子放出率、放射能、吸収線量、吸収線量率、カーマ、カーマ率、照射線量、照射線量率、線量当量又は 線量当量率
- Length, mass, time, electric current, temperature, amount of substance, luminous intensity, angle, solid angle, area, volume, angular velocity, angular acceleration, velocity, acceleration, frequency, rotational frequency, wave number, density, force, moment of force, pressure, stress, viscosity, kinematic viscosity, work, power, mass flow rate, flow rate, quantity of heat, thermal conductivity, specific heat capacity, entropy, quantity of electricity, electric field strength, voltage, electromotive force, capacitance, magnetic field strength, magnetomotive force, magnetic flux density, magnetic flux, inductance, electric resistance, electric conductance, impedance, active power, reactive power, apparent power, active energy, reactive energy, apparent energy, attenuation of electromagnetic wave, electric power density of electromagnetic wave, radiant intensity, luminous flux, luminance, illuminance, sound power, sound pressure level, oscillating acceleration level, concentration, neutron emission rate, radioactivity, absorbed dose, absorbed dose rate, kerma, kerma rate, exposure, exposure rate, dose equivalent or dose equivalent rate.
- プラズマ立ち上げ期間に、低密度ガス上燃料がガス注入装置により、真空容器内に注入される。プラズマは、外側リミタと接触しながら、円形状からプラズマ電流を立ち上げつつ非円形ダイバータ形状に進展する。ひとたび電流がフラットトップ値(定格運転では15 MA)に達すれば、追加熱とともに燃料供給(ガスまたはペレット)は高いエネルギー増倍率と約500 MWの核融合パワーの制御された燃焼をもたらす。加熱装置による非誘導電流駆動では、燃焼時間は3000秒に伸ばされると予想される。誘導シナリオでは、燃焼磁束を使い切る前に、燃料供給率を減らしながらゆっくりと核融合出力を下げて燃焼を休止する。誘導電流駆動によるパルス運転は、1800秒の短い繰り返し周期で、このうち燃焼時間は400秒の燃焼である。
- During plasma start-up, low-density gaseous fuel will be introduced into the vacuum vessel chamber by the gas injection system. The plasma will progress from a circular configuration to an elongated divertor configuration as the plasma current is ramped up. As the current develops (nominally up to 15 MA), subsequent plasma fueling (gas or pellets) together with additional heating leads to a high energy gain burn and finally to a controlled burn with a fusion power of about 500 MW. With non-inductive current drive from the heating systems, the burn duration is envisaged to be extended up to 3000 s. In inductive scenarios, before the inductive flux available has been fully used, reducing the fueling rate so as to slowly rampdown the fusion power terminates the burn. This phase is followed by plasma current rampdown and finally by plasma termination. The inductively driven pulse has a nominal burn duration of 400 s, with a pulse repetition period as short as 1800 s.
- アノード、カソード及びゲート端子を有するワイド・バンドギャップ・ゲート・ターンオフ・サイリスタ(GTO)と、ベース、コレクタ及びエミッタ端子を有するワイド・バンドギャップ・バイポーラ接合トランジスタ(BJT)であって、BJTのエミッタ端子がGTOのアノード端子に直接結合するワイド・バンドギャップ・バイポーラ接合トランジスタ(BJT)と、を備えるパッケージ化したバイポーラ・ターンオフ・サイリスタ・デバイスにおいて、バイポーラ・パワー・スイッチング・デバイスは、非導通状態と、BJTのベース端子への第一制御信号の印加とGTOのゲート端子への第二制御信号の印加とに応答してBJTのコレクタとGTOのカソードとの間に電流を流すことができる導通状態との間を切り替えるように構成されるパッケージ化したバイポーラ・ターンオフ・サイリスタ・デバイス。
- A packaged bipolar turn-off thyristor device, comprising: a wide bandgapvgate turn-off thyristor (GTO) having an anode, a cathode, and a gate terminal; and ?-, a wide bandgap bipolar junction transistor (BJT) having a base, a collector, and an emitter terminal, the emitter terminal of the BJT being directly coupled to the anode terminal of the GTO, wherein the bipolar power switching device is configured to switch between a nonconducting state and a conducting state that allows current flow between the collector of the BJT and the cathode of the GTO responsive to application of a first control signal to the base terminal of the BJT and responsive to application of a second control signal to the gate terminal of the GTO.
- アノード、カソード及びゲート端子を有するワイド・バンドギャップ・サイリスタと、ベース、コレクタ及びエミッタ端子を有するワイド・バンドギャップ・バイポーラ・トランジスタであって、バイポーラ・トランジスタのエミッタ端子がサイリスタのアノード端子に結合されるワイド・バンドギャップ・バイポーラ・トランジスタと、を備える電子デバイスにおいて、バイポーラ・トランジスタ及びサイリスタは、ワイド・バンドギャップ・バイポーラ・パワー・スイッチング・デバイスを特徴付け、ワイド・バンドギャップ・バイポーラ・パワー・スイッチング・デバイスは、非導通状態と、バイポーラ・トランジスタのベース端子への第一制御信号の印加及びサイリスタのゲート端子への第二制御信号の印加に応答してバイポーラ・トランジスタのコレクタ端子とサイリスタのカソード端子との間に電流が流れるような導通状態との間を切り替えるように構成される電子デバイス。
- An electronic device, comprising: a wide bandgap thyristor having an anode, a cathode, and a gate terminal; and a wide bandgap bipolar transistor having a base, a collector, and an emitter terminal, the emitter terminal of the bipolar transistor being coupled to the anode terminal of the thyristor, wherein the bipolar transistor and the thyristor define a wide bandgap bipolar power switching device that is configured to switch between a nonconducting state and a conducting state such that current flows between the collector terminal of the bipolar transistor and the cathode terminal of the thyristor responsive to application of a first control signal to the base terminal of the bipolar transistor and responsive to application of a second control signal to the gate terminal of the thyristor.
- ベース、コレクタ及びエミッタ端子を有するワイド・バンドギャップ・バイポーラ・トランジスタであって、コレクタ端子が、バイポーラ・パワー・スイッチング・デバイスの第一主端子に対応するワイド・バンドギャップ・バイポーラ・トランジスタと、アノード、カソード及びゲート端子を有するワイド・バンドギャップ・サイリスタであって、サイリスタのアノード端子が、バイポーラ・トランジスタのエミッタ端子に結合され、カソード端子が、バイポーラ・パワー・スイッチング・デバイスの第二主端子に対応するワイド・バンドギャップ・サイリスタと、を備えるパッケージ化したバイポーラ・パワー・スイッチング・デバイスにおいて、バイポーラ・パワー・トランジスタは、非導通状態と、第一及び第二主端子間に電流が流れるような導通状態との間を切り替えるように構成され、バイポーラ・パワー・トランジスタは、導通状態において第一及び第二主端子の間で非負の温度係数を有するバイポーラ・パワー・スイッチング・デバイス。
- A packaged bipolar power switching device, comprising: a wide bandgap bipolar transistor having a base, a collector, and an emitter terminal, the collector terminal corresponding to a first main terminal of the bipolar power switching device; and a wide bandgap thyristor having an anode, a cathode, and a gate terminal, the anode terminal of the thyristor being coupled to the emitter terminal of the bipolar transistor, and the cathode terminal corresponding to a second main terminal of the bipolar power switching device, wherein the bipolar power transistor is configured to switch between a nonconducting state and a conducting state such that current flows between the first and second main terminals, and wherein the bipolar power transistor has a non-negative temperature coefficient across the first and second main terminals in the conducting state.